Skip to main content
Header logo

ISO 15022
Data Field Dictionary

MT524: (5) Field 99B: Number Count

FORMAT

Option B :4!c//3!n (Qualifier)(Number)

PRESENCE

Optional in mandatory sequence A

QUALIFIER

(Error code(s): T89)

Order

M/O

Qualifier

R/N

CR

Options

Qualifier Description

1

O

SETT

N

C3

B

Current Instruction Number

2

O

TOSE

N

C3

B

Total of Linked Instructions

DEFINITION

This qualified generic field specifies:

SETT

Current Instruction Number

Sequential number of the instruction in a range of linked instructions.

TOSE

Total of Linked Instructions

Total number of instructions that are linked together.

USAGE RULES

The current instruction number must be specified when the Sender wants to indicate that this instruction is linked to one or more instructions.